S3000-UV-NIR
| |
Power supply | 5V DC provided by PC USB port |
Wavelength range | 190nm ~ 1100nm |
Detector | TCD1305 UV enhanced CCD |
Slit | 30um |
Grating | grating.600 grooves/mm@250nm 750nm |
Wavelength resolution | Depending on grating and slit, minimum to 0.2nm |
S/N ratio | 500:1 |
Scatter light | <0.1% |
CCD Linearity correction | 99.8% |
Power consumption | 95mA@5V |
Communication interface | USB2.0/RS232 |
A/D conversion | 16bit high precision AD |
Fiber interface | SMA905 |
Dimension | 115 mm(L) x 80 mm (W) x 40 mm (H) |
Weight | 500 g |
Minimum exposure time | 0.01ms |
Maximum exposure time | 60s |
Wavelength repeat error | < 0.3nm |
Wavelength absolute error | < 0.3nm |
Operating temperature | -40℃ ~ 85℃ |
Software | SpectraPro |
圖1 S3000-UV-NIR Range(185nm-1102nm)
圖2 S3000-UV-NIR RESOLUTION RATIO
Spectra Data
System configuration
A. Spectrometer S2000-UV or S2000-UV/NIR
B. Software SpectraPro V3.2
C. Adjustable halogen light source or Deuterium/Tungsten light source DH02
D. Reflectivity measurement accessories
E. Standard whiteboard
F: Y type optical fiber root (SMA905 interface)
C and E can be bought from us according to clients requirement.
Include:
Hardware and USB power line
Software SpectraPro V3.2 CD
User guide
Below lamp can be choosed with additional order
1. Adjustable tungsten light source H03
Feature
? Fiber Coupling
? VIA / NIR optical output
? High stability
? Compact
? long life
Typical spectral output
Technical Parameters
The spectral output range | 330nm~2600nm |
power | 10W |
Input Power | DC12V |
Operating temperature | -10~35℃ |
Settling Time | 1~2minutes |
size | 128mm(L) * 95mm(W) *53mm(H) |
weight | 420g(without optical fiber) |
Optical interface | SMA905(FC interface can be choosed) |
Recommendation fiber core diameter | 400um |
life | > 2000h |
SpectraAnalysis have multiple spectra line display,multiple spectra dispose,snapshot,buffer spectra, peak-searching/valley-searching,F(xiàn)WHM, coordinate convert,spectra recording functions. It mainly consist by Control Window 、Spectra Window and Spectra List Window. Control window used to change settings of USB data collection;Spectra Window display the current spectra or file spectra collect from USB and open spectra recording file;Spectra setting window mainly control the display style of spactra line. Text label, mouse right button spectra line move, prompt bar and mouse prompt in spectra graphic make the operation more convenient, and get the spectra line information easily. It can contract with Microsoft ,export the spectra data asExcel and Word files. The program will save the spectra as *.ssp files,double click or move file into window can open the spectra graphic.
2.Deuterium Light Source D03
D03 deuterium light source is the fiber coupling UV light source, covering the wavelength range 190nm-> 400nm, using 30W deuterium lamp as a light source, output interface with SMA905 interface. It is the best choice for UV transmission and absorbance spectra measurement.
Feature
? Fiber Coupling
? UV / VIS optical output
? High stability
? Compact
? long life
Typical spectral output
Performance parameters
The spectral output range | 190nm~400nm |
power | 30W |
Optical interface | SMA905 |
Input Power | DC 24V 2A |
Operating temperature | -10~35℃ |
size | 240mm(L) * 110mm(W) * 150mm(H) |
weight | 1.5Kg |
life | ~2000H |